Vol. 11, No 3: 71–78.

Medical Sciences

2026

Scientific article

UDK 618.5-07

pdf-version

Ulyana E. Taeva
specialist degree, Petrozavodsk State University
(Petrozavodsk, Russia),
taevaulyana@gmail.com

Cardiotocography in Asphyxia Prediction: Its Prognostic Value and the Role of Clinical Context

Scientific adviser:
Alexander A. Ivshin
Reviewer:
Julia Boldina
Paper submitted on: 09/28/2026;
Accepted on: 09/28/2026;
Published online on: 09/28/2026.
Abstract. The subjectivity of visual cardiotocography (CTG) interpretation limits the reliability of intrapartum foetal monitoring. The study aimed to assess the predictive value of CTG interpretation according to the FIGO classification and the role of meconium-stained amniotic fluid in predicting neonatal asphyxia. This was a retrospective cohort study (n=9,981) that applied ROC analysis and convergent validation. The area under the ROC curve (AUROC) was 0.595, with the treatment paradox and base rate effect depressing the observed association. The findings justify automated CTG interpretation as a clinical decision support tool.
Keywords: cardiotocography, FIGO classification, neonatal asphyxia, predictive value, convergent validation, meconium-stained amniotic fluid, treatment paradox, base rate effect, machine learning, clinical decision support system

For citation: Taeva, U. E. Cardiotocography in Asphyxia Prediction: Its Prognostic Value and the Role of Clinical Context. StudArctic forum. 2026, 11 (3): 71–78.

References

Al Wattar B.H., Honess E., et al. Effectiveness of intrapartum fetal surveillance to improve maternal and neonatal outcomes: a systematic review and network meta-analysis. Canadian Medical Association Journal, 2021, Vol. 193, No. 14, pp. E468–E477. DOI: 10.1503/cmaj.202538

Ayres-de-Campos D., Spong C.Y., et al. FIGO consensus guidelines on intrapartum fetal monitoring: cardiotocography. International Journal of Gynecology & Obstetrics, 2015, Vol. 131, No. 1, pp. 13–24. DOI: 10.1016/j.ijgo.2015.06.020

Ben M'Barek I., Ben M'Barek B., et al. Large-scale analysis of interobserver agreement and reliability in cardiotocography interpretation during labor using an online tool. BMC Pregnancy and Childbirth, 2024, Vol. 24, No. 1, Art. No. 136. DOI: 10.1186/s12884-024-06322-4

Grivell R.M., Alfirevic Z., et al. Antenatal cardiotocography for fetal assessment. Cochrane Database of Systematic Reviews, 2015, No. 9, Art. No. CD007863. DOI: 10.1002/14651858.CD007863.pub4

Kling D., Rehnström M., et al. Performance of five cardiotocography classification templates in labor: a cohort study. The Journal of Maternal-Fetal & Neonatal Medicine, 2024, Vol. 37, No. 1, Art. No. 2394845. DOI: 10.1080/14767058.2024.2394845

Neri S., Ramirez Zegarra R., et al. Interobserver agreement among midwives in cardiotocography interpretation using the 2015 FIGO guidelines for intrapartum fetal monitoring: a retrospective study. International Journal of Gynecology & Obstetrics, 2026, Vol. 173, No. 2, pp. 883–888. DOI: 10.1002/ijgo.70687

Vejux N., Ledu R., et al. Guideline choice for CTG analysis influences first caesarean decision. The Journal of Maternal-Fetal & Neonatal Medicine, 2017, Vol. 30, No. 15, pp. 1816–1819. DOI: 10.1080/14767058.2016.1228050

Zamora del Pozo C., Chóliz Ezquerro M., et al. Diagnostic capacity and interobserver variability in FIGO, ACOG, NICE and Chandraharan cardiotocographic guidelines to predict neonatal acidemia. The Journal of Maternal-Fetal & Neonatal Medicine, 2022, Vol. 35, No. 25, pp. 8498–8506. DOI: 10.1080/14767058.2021.1986479

Displays: 58; Downloads: 22;